Typical Clarus Environmental Turbine STEP System
Clarus Environmental Turbine STEP Systems are designed for installation in septic tanks. The system should be installed through the riser
on the discharge end of the septic tank. A complete system should include: 1) Filter and pump vault, 2) Filter cartridges, 3) Float tree/ switch
assembly, 4) Efuent rated turbine pump, 5) Discharge pipe assembly, 6) Control/alarm system, 7) Junction box, 8) Prewired conduit, 9) Riser
and lid.
SK2418
Fig. 1
4 1/2"
"B"
"C"
CLARUS J-BOX
SLUDGE LAYER
LENGTH FROM CLAMP
3 1/2" OF TETHER
CLEAR EFFLUENT
TEE OR BAFFLE
STANDARD 4" INLET
FLOAT SWITCH DETAIL
(MOUNTED ON HOUSE)
OR ALARM SYSTEM
4" MIN.
RISERS FOR DRAINAGE
SLOPE GROUND AWAY FROM
CLARUS CONTROL PANEL
TOP OF FILTER TANK
SCUM LAYER
* * * * * * *
* * * * * * *
* * * * * * * * * * * * * * * * * * * * * * * *
(INCLUDES FLEXIBLE PVC PIPE, UNION, BALL VALVE,
FROM PUMP TO SNUB OUTSIDE RISER
CLARUS DISCHARGE PIPE ASSEMBLY
AND PIPE SEAL)
FILTERED EFFLUENT
* * * * * * * * * * * * * * * * * * * * * * * *
INSTALLED INLET HOLE.
AVAILABLE FOR FIELD
NOTE: BLANK TANKS ARE ALSO
CLARUS PREWIRED
CONDUIT
TOP OF FLOAT TREE
"G"
CLARUS 12" RISER AND LID
HANGER PIPES
CLARUS FILTER ASSEMBLY
CLARUS PUMP VAULT
CLARUS EFFLUENT
TURBINE PUMP
1" x 16" SCH80
HANGER PIPES
ALARM
ALARM
ALARM
ALARM
---
A
PUMP ON PUMP OFF
CLARUS 24 OR 30 INCH ACCESS RISER & LID
K
31.5"
40"
31.5"
29"
41"
2.5"
2.5"
2.5"
8"
2.5"
2.5"
5"
5" 5"
---
---
---
---
H
"H" MIN.
26.5"
25.5"
30.5"
30.5"
30.5"
---
---
---
REDUNDANT OFF
---
---
---
PUMP OFF
PUMP OFF
LOW LEVEL CUTOUT
LOW LEVEL CUTOUT
PUMP ON
PUMP ON
TIMER OVERRIDE
TIMER OVERRIDE
------
30.5"
8"
---
JGFEDC
4 FLOAT TIMED DOSING PANEL
3 FLOAT SIMPLEX CONTROL PANEL
2 FLOAT SWITCH CONTROL W/ALARM
2 FLOAT SWITCH CONTROL
BFLOAT CONFIGURATION
3 FLOAT TIMED DOSING PANEL
"J" MAX.
"F" MAX.
"E" MIN.
"D" MIN.
DUPLEX PUMP
APPLICATION
SIMPLEX PUMP
APPLICATION
ALARM "A"
(BELOW, OR EVEN WITH, THE INLET HEIGHT)
INLET
"K" MIN.
8 1/8"
17 1/8
55 1/2"
SECURE EXCESS CORDAGE
(FOR FILTER REMOVAL)
18" MIN. OR
PER STATE AND
LOCAL CODES
ALL WORK IN ACCORDANCE
WITH NEC AND ANY OTHER
STATE OR LOCAL CODES
33"
TYPICAL
INLET LEVEL
8' 0" MIN.
3" MIN.